Monitoring

Metrics

All critical metrics are required to have a positive status for a functioning base station.

The following table outlines the hierarchy of severity of each metric. The metrics below depend on the metrics above.

â–‡ - Red coloured metrics are critical for a functioning base station

â–‡ - Yellow coloured metrics are informative but still affect the metrics below it

Power

VPN

Internet

Receiver

Noise Level

Online

Software

Last Message Time

Health

To sign up for Online and Health notification follow the instruction here:

Responsible Persons | Adding Responsible Personsarchived

Metric name

Description

Metric name

Description

1

Power

Station’s power-on history.

Uptime is the time passed since the latest boot.

2

Internet

Internet connection based on the ping status to Google’s DNS (8.8.8.8).

3

VPN

Connection status to the Nwave’s VPN server.

Connection to VPN requires access to 34.249.186.186:444 and 3.9.73.207:444

4

Online

Represents the status of a communication link between a base station and the Nwave’s cloud. To be online a station must have a working internet connection.

5

Receiver

Connection status of a receiver dongle.

6

Software

Running status of the signal decoding software.

7

Noise Level

History of noise level picked up by the station’s dongle.

8

Last Message Time

Time of the last received message.

9

Health

Represents the status of a communication link between a base station and the sensors. To be healthy a receiver must be connected and the software needs to be running

Â